| Image | Part Number | Manufacturer | Description | Voltage Rating - DC | Voltage Rating - AC | Switch Function | Series | Operating Temperature | Operating Force | Ingress Protection | Features | Current Rating |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 2CPSA1A2 | Honeywell Sensing and Productivity Solutions | SWITCH SNAP ACT 4PST 50MA 250V | 60V | 250V | On-Off, Off-On | CPS | -40°C ~ 80°C | - | IP67 - Dust Tight, Waterproof | - | 50mA (AC/DC) | |
| ER6022-022NESS | Omron Automation & Safety | ER6022-022NESS 2N/C+2N/O 1/2 " N | 24V | 120V | On-Off, Off-On | ER6022-SS | -25°C ~ 80°C | 12746gf | IP67 - Dust Tight, Waterproof | Push Button Emergency Stop Switch | 6A (AC), 2.5A (DC) | |
| 1CPSA3A | Honeywell Sensing and Productivity Solutions | SWITCH SNAP ACTION 4PST 10A 600V | 250V | 600V | On-Off, Off-On | CPS | -40°C ~ 80°C | - | IP67 - Dust Tight, Waterproof | LED Indicator | 10A (AC/DC) | |
| ER1022-042MELR | Omron Automation & Safety | ER1022-042MELR, 4N/C+2N/O, M20 | - | - | - | ER1022 | - | - | - | - | - | |
| 1CPSA2-N | Honeywell Sensing and Productivity Solutions | SWITCH SNAP ACTION 4PST 10A 600V | 250V | 600V | On-Off, Off-On | CPS | -40°C ~ 80°C | - | IP67 - Dust Tight, Waterproof | - | 10A (AC/DC) | |
| CLSC4B | Honeywell Sensing and Productivity Solutions | CABLE PULL LIMIT SW BLUE BODY | - | - | - | - | - | - | - | - | - | |
| 2CPSA2B1 | Honeywell Sensing and Productivity Solutions | SWITCH SNAP ACT 4PST 50MA 250V | 60V | 250V | On-Off, Off-On | CPS | -40°C ~ 80°C | - | IP67 - Dust Tight, Waterproof | - | 50mA (AC/DC) | |
| 44506-5422 | Omron Automation & Safety | ER6022-021NEL-125VDC, 2N/C+1N/O | - | - | - | - | - | - | - | - | - | |
| ER6022-022ML | Omron Automation & Safety | ER6022-022ML, 2 N/C+2 N/O, M20 | - | - | - | - | - | - | - | - | - | |
| 2CPSA2B1B | Honeywell Sensing and Productivity Solutions | SWITCH SNAP ACT 4PST 50MA 250V | 60V | 250V | On-Off, Off-On | CPS | -40°C ~ 80°C | - | IP67 - Dust Tight, Waterproof | LED Indicator | 50mA (AC/DC) |
Cable pull switches are safety devices used in industrial environments to provide emergency stop functionality. They consist of a switch mechanism connected to a cable. Pulling the cable activates the switch, halting machinery or equipment in hazardous situations. Cable pull switches are commonly found in manufacturing plants, conveyor systems, and assembly lines where quick and reliable shutdowns are crucial for worker safety and equipment protection. These switches offer a convenient means of emergency shutdown over large areas or distances.