| Image | Part Number | Manufacturer | Description | Series | Operating Temperature | Mounting Type | RoHS Status | Type | Output Type | Voltage Rating | Current | Output Configuration |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| SSF67A25B300PM12 | Cynergy3 | DL LVL FLOATSW 327MM TOTAL L | SSF67PM12 | 135°C | Panel Mount, M16x2 Thread | - | Liquid | Switch (2) (Single Float) | 120VDC, 250VAC | 600mA | SPST-NO, SPST-NC | |
| LLN865182-1 | Honeywell Sensing and Productivity Solutions | LLN LIQUID LEVEL SENSOR | LLN | -40°C ~ 125°C | - | - | Liquid | - | 10 ~ 40 V | 200mA | NPN | |
| SSF67V70S1000 | Cynergy3 | SENSOR LEVEL 70-1000MM 4-20MA | SSF67V | 135°C | Panel Mount, M16x2 Thread | - | Liquid | Analog (Single Float) | 120VDC, 240VAC | - | 4mA ~ 20mA | |
| VR2B | Carlo Gavazzi | LVL SEN CAP NYLON 1.5 IN THD | VR | -25°C ~ 70°C | Threaded | - | Liquid, Powder | - | 20 V ~ 30 V | - | - | |
| RSF106HVP | Cynergy3 | FLOATSWITCH VERT 100VA PPS | RSF100 | -10°C ~ 120°C | Panel Mount, M16x2 Thread | - | Liquid | Switch (Single Float) | 300VDC, 300VAC | 1A | SPST-NO | |
| SSF67A25B75PM12 | Cynergy3 | DL LVL FLOATSW 102MM TOTAL L | SSF67PM12 | 135°C | Panel Mount, M16x2 Thread | - | Liquid | Switch (2) (Single Float) | 120VDC, 250VAC | 600mA | SPST-NO, SPST-NC | |
| VPP110 | Carlo Gavazzi | LVL SNSR COND 1 PROBE 1IN PP | VN | 0°C ~ 100°C | Threaded | - | Liquid | Relay | - | - | - | |
| ILTSU-GI360-015 | Cynergy3 | SENSOR PRESSURE 0-360WG 4-20MA | ILTSU | -20°C ~ 60°C | Cable Mount | - | Liquid | Analog (Diaphragm) | 9 ~ 32 V | 28mA | 4mA ~ 20mA | |
| SSV66A35B135SM16 | Cynergy3 | SD MNT DUAL SW PNT FLTSW M17 | SSV66-SM16 | 120°C | Panel Mount, M16 Thread | - | Liquid | Switch (2) (Single Float) | 300VDC, 300VAC | 500mA | SPST-NO, SPST-NC | |
| LLC500D3L | SST Sensing | LIQUID LEVEL SENSOR | Optomax | -25°C ~ 80°C | Threaded | - | Liquid | Digital | 4.5 V ~ 15.4 V | 2.5mA | Push-Pull |
Float and level sensors are devices designed to detect liquid levels or fluid presence in tanks, reservoirs, or containers. These sensors utilize float switches, capacitance, conductivity, or ultrasonic principles to detect changes in liquid levels and provide output signals indicative of the fluid level status. Float and level sensors find applications in industries such as automotive, aerospace, wastewater treatment, food and beverage, and chemical processing for tasks such as liquid level monitoring, pump control, and liquid level alarm systems. They offer advantages such as reliability, versatility, and compatibility with different fluids and container materials, making them essential components in liquid level sensing and control applications.