| Image | Part Number | Manufacturer | Description | Series | Operating Temperature | Mounting Type | RoHS Status | Type | Output Type | Voltage Rating | Current | Output Configuration |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| SSF67A25B125PM12 | Cynergy3 | DL LVL FLOATSW 152MM TOTAL L | SSF67PM12 | 135°C | Panel Mount, M16x2 Thread | - | Liquid | Switch (2) (Single Float) | 120VDC, 250VAC | 600mA | SPST-NO, SPST-NC | |
| LLE103000-RS | Honeywell Sensing and Productivity Solutions | LIQUID LEVEL SENSOR | LLE | -25°C ~ 80°C | Panel Mount, M12 Thread | - | Liquid | Push-Pull | 5 V ~ 12 V | 15mA | High-Dry | |
| TSF76H100DN | Cynergy3 | THERMISTOR FLOAT SWITCH PPS 1A | TSF70 | -10°C ~ 120°C | Panel Mount, M16x2 Thread | - | Liquid, Temperature | Switch (Single Float) | 300VDC, 300VAC | 1A | SPST-NC/NO | |
| VH4 | Carlo Gavazzi | LEVEL HANGING PROBE W/O CBL | - | 0°C ~ 80°C | - | - | Liquid | Relay | - | - | SPDT | |
| CTANK-A710 | Digi International | TANK LEVEL MONITOR A710 | Digi Connect® | -30°C ~ 65°C | - | - | Liquid | Cellular | 7.2V | - | 3G/2G | |
| 59630-2-T-02-F | Hamlin / Littelfuse | REED SENSOR W/INTEGRAL FLOAT | 59630 | -20°C ~ 105°C | Panel Mount, M8 Thread | - | Liquid | Switch (Single Float) | 300V | 500mA | SPST-NO | |
| LLF46H100RF | Cynergy3 | FLOAT SWITCH 100VA PPS 1M PVC 16 | LLF40 | -10°C ~ 120°C | Male 1" (25.4mm) NPT | - | Liquid | Switch (Single Float) | 300V | 1A | SPST-NC/NO | |
| RSF54H100R1/8 | Cynergy3 | FLOATSWITCH VERT 1A NO/NC POLY | RSF50 | -20°C ~ 100°C | Male 1/8" (3.18mm) NPT | - | Liquid | Switch (Single Float) | 300VDC, 300VAC | 1A | SPST-NC/NO | |
| TSF43Y100DF | Cynergy3 | THERMISTOR FLOAT SW NYLON .6A | TSF40 | -20°C ~ 75°C | Panel Mount, M16x2 Thread | - | Liquid, Temperature | Switch (Single Float) | 120VDC, 240VAC | 600mA | SPST-NC/NO | |
| SSF67A25B200 | Cynergy3 | DL LVL FLOATSW 227MM TOTAL L | SSF67 | 135°C | Panel Mount, M16x2 Thread | - | Liquid | Switch (2) (Single Float) | 120VDC, 250VAC | 600mA | SPST-NO, SPST-NC |
Float and level sensors are devices designed to detect liquid levels or fluid presence in tanks, reservoirs, or containers. These sensors utilize float switches, capacitance, conductivity, or ultrasonic principles to detect changes in liquid levels and provide output signals indicative of the fluid level status. Float and level sensors find applications in industries such as automotive, aerospace, wastewater treatment, food and beverage, and chemical processing for tasks such as liquid level monitoring, pump control, and liquid level alarm systems. They offer advantages such as reliability, versatility, and compatibility with different fluids and container materials, making them essential components in liquid level sensing and control applications.